Professional solar cell panel manufacturer

Solar Panel DC Isolator Switch

Solar DC  isolator switch with IP66 enclosure for PV application, installed between the solar arrays and solar inverter, for isolation the PV array during system installation or any maintenance. The switch must be rated system voltage.

Physical Characteristics
Rated insulation voltage DC 1000V,1500V
Rated heating   32A
Waterproof Grade IP66
DC poles option 2P or 4P
Connection With or without MC4 Solar Connectors

 

分类:

描述

Solar DC isolator switches are suitable for isolating lines in high-voltage direct current transmission and distribution systems, such as cutting off high-voltage direct current between solar panels and inverters.
In the harsh working environment, it provides safe and reliable control of the power supply, high safety, and can be used with confidence.

Application:

Solar DC series isolator switch is suitable for a power system with rated voltage DC 1200v or below and rated current 32A or below.
The product can be used for infrequent switching-on and switching-off and can disconnect 1~2MPPT lines at thesame time. It is especially suitable for isolating lines in HVDC transmission and distribution systems, such ascutting off the high voltage direct current between solar panels and inverters.

Structure:

lnstalled at any angle can achieve lP66waterproof level
UV resistance and Vo flame retardant material
Contact Silver Plating, silver layer thickness tothe industry’s highest standards
Arcing Time in 3ms
No Polarity
Lockable at OFF position
Breather valve attached on the bottom of the isolator
AS 60947.3:2018 and lEC 60947.1:2015 Standard
5 years warranty, product insurance, and recallinsurance available

Technical Data:

Data according to IEC/EN60947-3:2009 + A1 + A2, AS60947.3, Utilization category DC-PV1, DC-PV2

Main Parameters S1EL/N32/4
Rated Insulation Voltage Ui V 1500
Rated thermal current Ith A 32
Rated impulse withstand voltage Uimp V 8000
Rated short circuit breaking capacity lcw A 1000
Maximum cable cross-sections(incl.jumper)
Solid standard mm² 45032
Flexible mm² 45026
Flexible(+multicore cable end) mm² 45026
Torque
Tightening torque terminal screws M4 Nm 1.2-1.8
Tightening torque shell mounting 1.5-2.0
screws ST4.2(304 stainless steel)
Tightening torque knob screws M3 Nm 0.5-0.7
Switching on or off Torque Nm 0.9-1.3
The wiring Torque on Base Nm 1.1-1.4
General parameters
Knob Positions OFF at 9 hr, ON at 12 hr ON at 3hr
Mechanical life 1000
Number of DC poles 2 or 4(6.8 optional)
Operation temperature -40 to +85
Storage temperature -40 to +85
Pollution degree 2
Overvoltage category III
IP rating IP66
Technical Data :
Data according to IEC/EN60947-3 2009+A1+A2. AS60947.3, Utilization category DC-PV1, DC-PV2
300V 600V 800V 1000V Pole No.of Strings Part Number
PV1 PV2 PV1 PV2 PV1 PV2 PV1 PV2
32 32 32 32 32 16 16 9 2 1 S1 EL(DB)/N32-2
32 32 32 32 32 16 16 9 4 2 S1EL(DB)/N32-4
32 32 32 32 32 32 32 32 4 1 S1EL(DB)/N32-4S
32 32 32 32 32 32 32 32 4 1 S1EL(DB)/N32-4B
32 32 32 32 32 32 32 32 4 1 S1EL(DB)/N32-4T
Switching Configurations :

Data according AS60947-3:2018
Main Contacts Type S1EL(DB)/N32 Appendix B5
Rated thermal current Ithe A 32 \
Rated insulation voltage Ui V 1000 \
Distance of contacts (per pole) mm 8 5x
Rated operational current le (DC-PV2) operations
1 pole
1
300V A 25 100
400V A 10 40
500V A 8 32
600V A 8 32
800V A 3 12
1000V A 2 8
4-pole
2 pole in series
4
500V A 32 128
600V A 13 52
700V A 9 36
800V A 9 36
900V A 9 36
1000V A 9 36
2-pole
4 pole in series
2H
500V A 40 160
600V A / /
700V A / /
800V A / /
900V A / /
1000V A / /
2-pole
4 pole in series
4B
500V A 32 128
600V A 32 128
700V A 32 128
800V A 32 128
900V A 32 128
1000V A 32 128

评价

目前还没有评价

成为第一个“Solar Panel DC Isolator Switch” 的评价者

您的电子邮箱地址不会被公开。 必填项已用*标注